mirror of
https://github.com/Ryujinx/SDL.git
synced 2025-03-22 23:35:05 +00:00
ibus: Handle error when getting the D-Bus machine ID
It is possible for retrieving the machine ID to fail, either because dbus was installed incorrectly (machine ID absent or corrupt), or in 32-bit builds, because stat() on the machine ID fails with EOVERFLOW if it has an out-of-range timestamp or inode number. dbus has historically treated this as a faulty installation, raising a warning which by default causes the process to crash. Unfortunately, dbus_get_local_machine_id() never had a way to report errors, so it has no alternative for that (bad) error handling. In dbus >= 1.12.0, we can use dbus_try_get_local_machine_id() to get the same information, but with the ability to cope gracefully with errors. ibus won't work in this situation, but that's better than crashing. (cherry picked from commit 91198baed40d5709020c3001e9234f4580df696a) Mitigates: https://github.com/ValveSoftware/steam-for-linux/issues/9605 Signed-off-by: Simon McVittie <smcv@collabora.com>
This commit is contained in:
parent
a3d4fd71c3
commit
4ce5c3a694
|
@ -36,6 +36,9 @@ static SDL_DBusContext dbus;
|
|||
|
||||
static int LoadDBUSSyms(void)
|
||||
{
|
||||
#define SDL_DBUS_SYM2_OPTIONAL(x, y) \
|
||||
dbus.x = SDL_LoadFunction(dbus_handle, #y)
|
||||
|
||||
#define SDL_DBUS_SYM2(x, y) \
|
||||
if (!(dbus.x = SDL_LoadFunction(dbus_handle, #y))) \
|
||||
return -1
|
||||
|
@ -43,6 +46,9 @@ static int LoadDBUSSyms(void)
|
|||
#define SDL_DBUS_SYM(x) \
|
||||
SDL_DBUS_SYM2(x, dbus_##x)
|
||||
|
||||
#define SDL_DBUS_SYM_OPTIONAL(x) \
|
||||
SDL_DBUS_SYM2_OPTIONAL(x, dbus_##x)
|
||||
|
||||
SDL_DBUS_SYM(bus_get_private);
|
||||
SDL_DBUS_SYM(bus_register);
|
||||
SDL_DBUS_SYM(bus_add_match);
|
||||
|
@ -80,6 +86,7 @@ static int LoadDBUSSyms(void)
|
|||
SDL_DBUS_SYM(error_is_set);
|
||||
SDL_DBUS_SYM(error_free);
|
||||
SDL_DBUS_SYM(get_local_machine_id);
|
||||
SDL_DBUS_SYM_OPTIONAL(try_get_local_machine_id);
|
||||
SDL_DBUS_SYM(free);
|
||||
SDL_DBUS_SYM(free_string_array);
|
||||
SDL_DBUS_SYM(shutdown);
|
||||
|
@ -493,6 +500,40 @@ SDL_bool SDL_DBus_ScreensaverInhibit(SDL_bool inhibit)
|
|||
|
||||
return SDL_TRUE;
|
||||
}
|
||||
|
||||
/*
|
||||
* Get the machine ID if possible. Result must be freed with dbus->free().
|
||||
*/
|
||||
char *SDL_DBus_GetLocalMachineId(void)
|
||||
{
|
||||
DBusError err;
|
||||
char *result;
|
||||
|
||||
dbus.error_init(&err);
|
||||
|
||||
if (dbus.try_get_local_machine_id) {
|
||||
/* Available since dbus 1.12.0, has proper error-handling */
|
||||
result = dbus.try_get_local_machine_id(&err);
|
||||
} else {
|
||||
/* Available since time immemorial, but has no error-handling:
|
||||
* if the machine ID can't be read, many versions of libdbus will
|
||||
* treat that as a fatal mis-installation and abort() */
|
||||
result = dbus.get_local_machine_id();
|
||||
}
|
||||
|
||||
if (result) {
|
||||
return result;
|
||||
}
|
||||
|
||||
if (dbus.error_is_set(&err)) {
|
||||
SDL_SetError("%s: %s", err.name, err.message);
|
||||
dbus.error_free(&err);
|
||||
} else {
|
||||
SDL_SetError("Error getting D-Bus machine ID");
|
||||
}
|
||||
|
||||
return NULL;
|
||||
}
|
||||
#endif
|
||||
|
||||
/* vi: set ts=4 sw=4 expandtab: */
|
||||
|
|
|
@ -72,6 +72,7 @@ typedef struct SDL_DBusContext
|
|||
dbus_bool_t (*error_is_set)(const DBusError *);
|
||||
void (*error_free)(DBusError *);
|
||||
char *(*get_local_machine_id)(void);
|
||||
char *(*try_get_local_machine_id)(DBusError *);
|
||||
void (*free)(void *);
|
||||
void (*free_string_array)(char **);
|
||||
void (*shutdown)(void);
|
||||
|
@ -95,6 +96,8 @@ extern SDL_bool SDL_DBus_QueryPropertyOnConnection(DBusConnection *conn, const c
|
|||
extern void SDL_DBus_ScreensaverTickle(void);
|
||||
extern SDL_bool SDL_DBus_ScreensaverInhibit(SDL_bool inhibit);
|
||||
|
||||
extern char *SDL_DBus_GetLocalMachineId(void);
|
||||
|
||||
#endif /* HAVE_DBUS_DBUS_H */
|
||||
|
||||
#endif /* SDL_dbus_h_ */
|
||||
|
|
|
@ -410,7 +410,12 @@ static char *IBus_GetDBusAddressFilename(void)
|
|||
(void)SDL_snprintf(config_dir, sizeof(config_dir), "%s/.config", home_env);
|
||||
}
|
||||
|
||||
key = dbus->get_local_machine_id();
|
||||
key = SDL_DBus_GetLocalMachineId();
|
||||
|
||||
if (key == NULL) {
|
||||
SDL_free(display);
|
||||
return NULL;
|
||||
}
|
||||
|
||||
SDL_memset(file_path, 0, sizeof(file_path));
|
||||
(void)SDL_snprintf(file_path, sizeof(file_path), "%s/ibus/bus/%s-%s-%s",
|
||||
|
|
Loading…
Reference in a new issue