In do_interrupt64(), when interrupt stack table(ist) is enabled
and the the target code segment is conforming(e2 & DESC_C_MASK), the
old implementation always set new CPL to 0, and SS.RPL to 0.
This is incorrect for when CPL3 code access a CPL0 conforming code
segment, the CPL should remain unchanged. Otherwise higher privileged
code can be compromised.
The patch fix this for always set dpl = cpl when the target code segment
is conforming, and modify the last parameter `flags`, which contains
correct new CPL, in cpu_x86_load_seg_cache().
Backports commit e95e9b88ba5f4a6c17f4d0c3a3a6bf3f648bb328 from qemu